The receiver drier will store the refrigerant until the evaporator requires it, ensuring that only liquefied refrigerant flows to the evaporator. Secondly the refrigerant is filtered and dried. After separation of gas and liquid, liquid refrigerant flows to the expansion valve.
SMP® designs and manufactures receiver driers made of either steel or aluminum. The receiver driers are available in form of Standalone Receiver Drier (Conventional type – RD is separated from the condenser) or Integral Receiver Drier (Newer design – RD is integrated with the condenser)
SMP® designs and manufactures receiver driers available in a variety of fits, forms, and functions, including:
TEST / CONDITION | SPECIFICATIONS |
Operating Temperature |
- 40℃ to +120℃ |
Corrosion Resistance |
120 to 1000 hrs SST |
Leakage |
Max leak 5g/year |
Burst Pressure |
Min 8.97MPa |
Pressure Durability |
Min 3.5MPa |
Moisture Absorption |
Min 14.5% |
Compatibility |
R134a / R1234yf / PAG |
Fit and Function |
Precision machined fittings to meet |